Quantcast
Channel: SCN : Discussion List - SAP PowerBuilder
Browsing all 286 articles
Browse latest View live

Buy SAP SQL Anywhere 17

Hello, Does anyone know where we could buy SAP Sql Anywhere 17 database? In SAP Store I don't have this option. We are from Slovenia. Thanks Tomaz

View Article


Documentation for older PB versions

Dear all,  I start this thread in order to ask if it is possible to access documentation & supported platforms resources for older PowerBuilder versions (5, 7, 8, 9). In Infocenter Archieve, I have...

View Article


Problem with SetFullState and Datastore residing in NVO objects in PB 11.2

Our program consists of a Main window holding all of our NVO objects for retrieving/updating data.  References to the NVO's are passed to the userobjects located on the window.  The NVO has 2...

View Article

Image may be NSFW.
Clik here to view.

DW / DropDownListBox Bug (PB 12.6/Builder 4088)

PB 12.6 Build 4088 Hi All, I think I have a bug, but do not know if it is addressed, or known, or I am crazy! Bug: I am trying to apply a simple Edit/Style/DropDownListBox to a string column in a...

View Article

Chris Pollack - I cannot reply to anything

Jeff Duke here from 'Problem with SetFullState and Datastore residing in NVO objects in PB 11.2' issue -I tried to reply to your post, my original post, direct communications and I keep getting error...

View Article


PowerBuilder Network Printer

I need to print to a printer on the network. I added the printer (COWORKERDSKTP) to my printers on my PC - it is not set as the default.I went to notepad and was able to print a sample to this printer....

View Article

Retrieval of datawindow crashes PowerBuilder

Hello All - I am facing a weird issue with PowerBuilder There is a datawindow which is constructed using a query at compile time, and another query is set to the datawindow at runtime using the Modify...

View Article

Webservice server

Hello, We have PB 11.2 and ASA 9I would like to ask if I could create webservice server  with PB or just client. Our customer would like to get data from our database with webservice calls so I have to...

View Article


Powerbuilder 12.6 will not install on Windows 10

Hi, I am trying to install Powerbuilder 12.6 Evaluation on a Windows 10 stand-alone PC (64 bit , 12GB memory). I choose to install Powerbuilder Classic only (no .NET or web stuff). After the option to...

View Article


Image may be NSFW.
Clik here to view.

SaveAs fails on PB Classic 12.5 using .Net Windows Forms target

Hi guys,I'm using PB12.5.2 Build 5550 on a Windows 7 SP1 32-bit machine. I have a NVO that receives a dataStore as argument. At the end of the processing I try to do a SaveAs on the DS. If I supply...

View Article

My application keeps crashing on Windows Server 2012 R2.

Powerbuilder 10.5 Since migrating to a Windows Server 2012 R2 Terminal Server my application keeps crashing. On the old Windows Server 2003 TS it worked fine.From the event log Windows cannot access...

View Article

Exporting the Datawindow Syntax in XML using PowerScript in PB

Hi All, PowerBuilder 12.6 IDE allows us to export/Save As File  the Datawindow Syntax into XML format. But when trying to look into LibraryExport don't find any option to perform the same using the...

View Article

Save As XLSX file crashes PowerBuilder

Hello All - We have an application we recently upgraded from 11.2 to 12.6 The PB 12.6 build version is 4091 (Chris - I guess that is the latest release version) Previously, the client used to save...

View Article


Licensing question

Hi,  I wish to purchase a single licence for PB 12.6. As it (initial GA build) will not run on any of my Windows 10 Intel computers I will be working on a Windows 7 virtual machine. Now, if SAP comes...

View Article

ports that pb 12.6 use

Hi, As part of security audit of our systems, Power Builder 12.6 was a subject of such an audit.As a result, a few findings were found as problematic and need more clarification from a vendor side.A...

View Article


Where do we download PB 12.5.2

Hi all - help - where can I get the PB 12.5.2 download as it has been removed from the sybase.subscribenet.com site - help please.....we have the licensing, but SAP has been less than helpful - telling...

View Article

Does PB 12.6 Corrupt long nvarchars in SA with DisableBind=1 ??

I've been investigating an issue migrating our 10.5 apps which use rich text edits and save data to a SQL Anywhere 12 database on a long nvarchar column. It works perfectly in 10.5 but in 12.6 the text...

View Article


Tuxedo Error - Powerbuilder 12.6 + Tuxedo 12.1.3

Hi All, I am getting an error in Powerbuilder 12.6 while connecting to Tuxedo 12.1.3 The error that i get is "Failed to allocate Receive Buffer. Tuxedo will not be available" .Can you please help.

View Article

Web Service Returns Data Type Any

I am calling a Web Service in PB 12.5. The proxy builder says that the web service returns type "any."   I used SoapUI to see what it really returns, and the web service is returning XML. I don't know...

View Article

Image may be NSFW.
Clik here to view.

Nested Datawindow Printing

I have a dw that contains a nested dw in the middle. Let's assume the space I have on the master dw that is allotted to the nested dw is 4 inches. I want the space allotted for the nested dw to stay...

View Article
Browsing all 286 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>